1. The MS maximum output power shall be as defined in GSM05.05, 4.1.1, first table, according to its power
class, with a tolerance of +/- 2 dB under normal conditions; GSM 05.05, 4.1.1, first table.
2. The MS maximum output power shall be as defined in GSM05.05, 4.1.1, first table, according to its power
class, with a tolerance of +/- 2,5 dB under extreme conditions; GSM 05.05, 4.1.1, first table; GSM 05.05 annex
D D.2.1, D.2.2.
3. The power control levels shall have the nominal output power levels as defined in GSM 05.05, 4.1.1, third table
(for GSM 400 and GSM 900) or fourth table (for DCS 1 800), from the lowest power control level up to the
maximum output power corresponding to the class of the MS (for tolerance on maximum output power see
conformance requirements 1), with a tolerance of +/- 3, 4 or 5 dB under normal conditions; GSM 05.05, 4.1.1,
third or fourth table.
4. The power control levels shall have the nominal output power levels as defined in GSM 05.05, 4.1.1, third table
(for GSM 400 and GSM 900) or fourth table (for DCS 1 800), from the lowest power control level up to the
maximum output power corresponding to the class of the MS (for tolerance on maximum output power see
conformance requirements 2), with a tolerance of +/- 4, 5 or 6 dB under extreme conditions; GSM 05.05, 4.1.1,
third or fourth table; GSM 05.05 annex D D.2.1, D.2.2.
5. The output power actually transmitted by the MS at consecutive power control levels shall form a monotonic
sequence and the interval between power control levels shall be 2 +/- 1,5 dB; GSM 05.05, 4.1.1.
...........................................................................................................
GSM欧洲电信标准(pdf 3137)摘要结束,